99精品国产免费观看视频-99re这里只有精品国产-九九热线精品视频26-99re6热这里在线精品视频
?
Nitrogen spring charging power unit

Applications

Nitrogen spring charging power unit HPB-1100-034P4B034
Suitable for inflating, washing and pressure test to hoses, pipes, valves, fittings and other hydraulic vessels and products.

1.Table top dual boosters unit, allows quick and easy charging of nitrogen gas springs and systems from nitrogen bottles.
2.Components include P4B booster, filter, pressure regulator, shut-off valve, unloading valve, pressure gauge, air hose, inflatable quick female connector, etc.
3.Standard plate type power unit with dual head booster. Compact and easy to control.
4.Nitrogen gas spring charging specific unit. Mounted with a 3m long charging hose. Outlet of hose has a shut-off valve, unloading valve. Quick female connector which is connected with nitrogen gas spring can control nitrogen gas charging precisely.
5.Other options: HPB-1100-P4B034 (single head booster, 235 bar), high pressure regulating valve, high pressure overflow valve, portable box.

1.Test medium: inert gases such as nitrogen and helium;
2.Test pressure: input<6.9 bar, output<235 bar;
3.Power supply: clean and dry compressed air, 1.0Nm3/Min@6.9 bar;
4.Dimensions and weight: L640*W260*H300(mm), 18kg;
5.More: HPB-1100-P4B034(sigle-ended booster, 235 bar), high pressure regulator, high pressure relief valve, portable case are optional.

99精品国产免费观看视频-99re这里只有精品国产-九九热线精品视频26-99re6热这里在线精品视频